OTHER ENGINE TYPES
Jenbacher Type 2: J208
Introduced in 1976, INNIO's Jenbacher Type 2 gas engine offers high efficiency power with a robust design.
The stationary engine concept provides excellent durability, while enhanced components and a proven control and monitoring model give the Type 2 engine outstanding reliability.
~1,250 engines delivered since 1976.
J208 – efficient L8-cylinders power generation solution for small/mid scale businesses.
-
RESOURCES



Change the scope of supply by clicking on a thumbnail.
Scope of supply:
* Provided technical data is for information only. Data ranges are calculated considering various gas quality levels and ambient conditions (standard or hot/tropical conditions, etc.).
Jenbacher can change the technical data unilaterally. In the case of such change, we will update the data on our pages as soon as we can.
Please reach out to our experts to get help with engines selection, obtain the technical parameters for your gas composition.
Output and efficiency at generator terminals. Energy input is according to DIN ISO 3046 and DIN 6271, respectively, with a tolerance of + 5%.
All data according to full load and subject to technical development and modification.
Based on emission values of 250 and 500 mg/Nm3 NOx at 5% O2 at dry exhaust gas.
Base for biogas and sewage gas versions: 65% CH4 / 35% CO2.
Base for landfill gas version: 55% CH4 / 40% CO2 / Rest N2.
L: 4,250 x W: 1,600 x H: 2,450 mm
L: 168 x W: 63 x H: 97 inches
L: 4,500 x W: 1,900 x H: 2,450 mm
L: 177 x W: 75 x H: 97 inches
L: 12,200 x W: 2,500 x H: 2,600 - 5,000 mm
L: 480 x W: 100 x H: 115 - 200 inches
Highlights of Jenbacher Type 2 engines
With their durability, reliability, and fuel flexibility, Jenbacher Type 2 gas engines have an unmatched worldwide reputation of getting the job done.
- High-performance long-life spark plug for reliable operation.
- Applicable heat sources include engine cooling water, oil, mixture gas, and exhaust gas.
- Applicable gas types include: natural gas, associated petroleum gas (flare gas), propane, biogas, sewage gas, landfill gas, coal mine gas, other special gases (e.g. coke, wood, and pyrolysis gases).
A perfect fit for applications up to 1MW across various industries.
Scope of supply:
Scope of supply, dedicated for applications, which require power generation only. If you are looking for simultaneous power and heat generation, please consider Combined Heat and Power Module (CHP Module) scope of supply.
Minimum scope of supply for genset:
- Engine and alternator installed on the frame
- Control panel
- Gas train
The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs.
Gensets can be installed inside a building or inside a container. To see more details about our containerized solutions, click here.
Combined Heat and Power Module (CHP Module) solutions allow customers to generate power and heat simultaneously at a very high total efficiencies, reaching 90% and even more.
Usual scope of supply:
- Engine and alternator installed on the frame
- Control panel, gas train
- Heat exchangers including exhaust gas heat exchanger
CHP Modules can generate hot water or steam at various parameters and can be integrated with your existing heat infrastructure. You can select the option that fits your project’s needs among the various heat recovery schemes provided by Jenbacher.
The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs.
CHP Modules can be installed inside a building or inside a container. To see more details about Jenbacher’s containerized solutions, click here.
Jenbacher’s containerized solutions are “ready-to-use” power plants, allowing customers to minimize commissioning time. Jenbacher has produced containerized power plant solutions for decades, providing customers state of the art power generation technologies wrapped in well-designed, reliable packages.
Both genset and CHP module solutions can be supplied as containerized versions depending on your needs.
Usual scope of supply:
- Engine and alternator installed on the frame
- Control panel, gas train
- Container with integrated ventilation system
- Cooling systems
- Lube oil supply system
- Exhaust gas heat exchanger (for CHP module)
The scope of supply can be extended further with various balance of plant options (BOP), reach out to our specialists for help in selecting scope of supply and BOP options to fulfill your project’s needs.
Balance of Plant (BOP)
The right auxiliary equipment is of critical importance in ensuring that a power solution is economically feasible and provides your business with reliability, availability, and efficiency. Click on the provided BOP options to learn more.
Reach out to our experts to select the configuration that fits your business’ needs.
Available BOP elements may vary, depending on the engine and application type.
Total flexibility
Depending on customer needs, the Type 2 can use a variety of gas types to increase efficiency levels and reduce industrial emissions.
Reliability for all scenarios
The Jenbacher Type 2’s turbocharger bypass is able to compensate for extreme operating conditions.
Complete efficiency
Enhanced combustion provides maximum efficiency, no matter how it’s being used or what fuel is desired.
Type 2 Case studies

Dettenhausen (GER)
thanks to a partnership between industry and municipal utilities
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Hyosung (KOR)
with Asia Pacific’s first 100% hydrogen engine power plant
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Coastal power plant in Kiel (GER)
Jenbacher large engines in Kiel ready for Hydrogen
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Biohof Querdel (GER)
A contribution to the energy transition in Germany
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

El Gabar Al Asfar Wastewater Treatment Plant (EGY)
boosts power and cuts costs at one of Egypt’s largest wastewater treatment facilities
Location
Installed engines
Electrical output
Thermal output
Total efficiency
Energy source
Commissioned

CN Paper Mill (CHN)
Solution reduces costs while converting waste to energy
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned







Dettenhausen (GER)
thanks to a partnership between industry and municipal utilities
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Hyosung (KOR)
with Asia Pacific’s first 100% hydrogen engine power plant
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Coastal power plant in Kiel (GER)
Jenbacher large engines in Kiel ready for Hydrogen
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

Biohof Querdel (GER)
A contribution to the energy transition in Germany
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned

El Gabar Al Asfar Wastewater Treatment Plant (EGY)
boosts power and cuts costs at one of Egypt’s largest wastewater treatment facilities
Location
Installed engines
Electrical output
Thermal output
Total efficiency
Energy source
Commissioned

CN Paper Mill (CHN)
Solution reduces costs while converting waste to energy
Location
Installed engines
Electrical output
Thermal output
Energy source
Commissioned
Our Services
Jenbacher Services
Bringing proven outcomes across the life cycle of your gas engines means less unplanned downtime, greater workforce efficiency, and lower operating costs. From commissioning to overhauling, our global network of qualified service experts provides the support you need, when you need it, by providing the latest technology.
Consult an expert
Send us a message and we’ll contact you to start the conversation.